Cooling systems
With the emergence and further increasing development of IT equipment, especially the new generation of servers, there was a problem of higher heat dissipation. Therefore, it is necessary to apply the appropriate solution in terms of cooling the server room, 356 days a year, 24 hours a day. ENEL PS as a distributor offers effective solutions based on the needs of investors and its desire in the form of APC solutions. APC offers solutions InRow and inroom that have a large flexibility (for large heat dissipation systems, changeable dissipation and dimensionally not occupying the large space in the data center).
InRow system was invented by APC and many international companies is developing this cooling concept. System with InRow units consists in setting the appropriate units between Rack cabinet and works on the principle that takes the warm air close to the rack cabinet, on the location of its source (hot zone), so injects cold air on the very rack enclosure (cold zone). On the basis of the cooling medium used InRow systems can be direct-expansion (the use of ecological Freon R-407C or R-410A, a refrigerant and an adequate external condenser cooling freon) or chillers - external cooling engine )which uses water as a cooling fluid or a mixture of water/glycol in the relevant respect) or chiller with free cooling (chiller has an additional heat exchanger which allow usage at temperature below 10°C) for greater system efficiency and lower power consumption.
Modular cooling system inroom Data Centers offers cost - effective and new approach to cooling and cooling - sensitive IT equipment.
APC technologies offers more cooling system, depending on the applied technology system and the cooling medium.
The basic division is on the following systems: direct expansion chiller system and Chiller systems are further divided according to the method of cooling:
Systems with direct expansion are divided according to the method of cooling:
For any cooling system to choose, help of our engineer is needed to select the best quality and most optimal solution.
InRow Cooling
The modern concept of air conditioning systems solves the problem by creating an incresing dissipation of IT equipment. Modular system InRow cooling Data Centers offers effective and economical cooling and a new approach to cooling of sensitive IT equipment. APC technologies offer more cooling system:
InRow Chilled Water
InRow Chilled Water cooling system provides directed cooling and eliminates the mixing of the warm and cold air. They are designed to increase efficiency and meet various demands of air conditioning medium at large data centers. InRow Chilled Water cooling system uses cold water, or more precisly a mixture of glycol and water, and its capacity depends on the type of use: open or closed cooling system. InRow Chilled Water cooling system is characterized by features such as: Each unit is equipped with variable speed fans which are individually replaceable when operationg the device, reducing MTTR. Internal tubes containing fluid flow meter, which communicates with microprocessor control The valve control the flow of microprocessor controls/regulates the amount of fluid to maintain optimum conditions. The device has power redundancy Condenser panel is designed as a high-sensitive on the difference in temperature The device has a network card to access over IP, which allows you to manage and control the cooling system Temperature sensor control devise inlet temperature based on the racks and set parimeters The device has cable-water leak sensor placed under the pipes and equipment. In case of water detection, trigers the alarm.
More information can be found at: http://www.apcc.com/products/family/index.cfm?id=339
InRow Direct Expansion
More information can be found at: http://www.apcc.com/products/family/index.cfm?id=379 InRoom Cooling System
The modern concept of air conditioning systems solves the problem of creating more and more heat dissipation of IT equipment. Modular cooling system Inroom Data Centers offers cost-effective and new approach to cooling and cooling-sensitive IT equipment. APC technologies offer more cooling system, depending on the applied technology and the cooling medium: Chilled water, which are used as a refrigerent cooling water or a mixture of water/glycol, which comes from the cooling unit and a direct expansion of the medium as Freon (R-407C or R-410A), cooled in external exchangers-condenser.
InRoom Chilled Water
Inroom Chilled Water Systems provide effective and flexible cooling solutions for low density racks and non-IT rack's load. These cooling systems are designed for data centers and provide efficient cooling at the server room. Inroom Chilled Water offers flexible and easy folding solutions through technology variable fan and intelligent control solutions for greater efficiency. APC offers a chiller outside the basic units in various sizes, depending on their size and the need for heat dissipation. The basic division is by inroom Chiller: dimensions (ie size cooling effect), the direction of air flow which cools, the number of cooling circuits (1 or 2) the method of cooling. According to size, dimensions and cooling capacity there are 5 models. Under the direction of air flow which cools, next model systems are available: a model that injects air into the raised floor and retracts at top and a model that injects air up and pulled the air in front of the inroom unit. According to the manner/method of cooling:
Classic chiller-water system with external cooling aggregate - CW system Chilled water system use a combination of glycol and CW for 2 cooling heat exchanger - GCW system Chilled Water system with cooling unit and an external capacitor DX (with two cooling heat exchanger) - ACW system
More information can be found at: http://www.apcc.com/products/family/index.cfm?id=380
InRoom Direct Expansion Inroom Direct Expansion (DX) provide effective and flexible cooling solutions for rack density and lower non-IT racks' load. Available in configurations all in one, air-cooled, water-cooled, glycol, multi-cooling and economizer, these products can be applied to different requirements in the IT environment. For the server room where cooling is non initially specified, inroom DX provides a complete portable solution content without the need for a remote heat exchanger. From small to large data centers, inrrom DX offer flexible, easy folding solutions through technology variable fan and intelligent control solutions for greater efficiency. APC offers all types of remote heat-capacitors that can be adapted for other configurations of data center. The basic division inroom DX units, according to: size (ie. Size cooling effect), the direction of air flow which cools, the number of cooling circuits (1 or 2) the method of cooling. According to size, dimensions and cooling capacity there are 5 models. Under the direction of airflow that cools, it returns to the inroom unit are available, the following systems: a model that injects air into the raised floor and retracts at top and a model that injects air up and pulls at front of the inroom unit. According to the manner/method of cooling: Inroom system with direct expansion and external (A) air-cooled condenser - A system Inroom system with direct expansion A similar system, but with an additional plate capacitor within inroom unit that uses a mixture of glycol/water heat dissipation and external air-cooled dry-cooler - G system Inroom system with free cooling and the evaporator, with an additional plate capacitor within inroom unit that uses a mixture of glycol/water heat dissipation (when lower ambient temperature) and external air-cooled dry-refrigerator - GE system
More information can be found at: http://www.apcc.com/products/family/index.cfm?id=381
Additions for cooling
APC accessories for cooling in the rack to fit modern concept of air conditioning systems, solving the problem created by the increasing dissipation of It equipment. They are achieved by improving the cooling and uniform temperature of equipment from the bottom to the top of the rack, while eliminating air mixing. APC presents a series of products for distribution of air that specifically integrate into the rack cabinets or solving the problems of inadequate cooling equipment into the rack. Compatible models with racks 600 and 750mm wide are available. APC offers multiple systems in this technology:
Rack Air Distribution Unit It is known that cooling of the double floor has its limits in case of increase in consumption in the racks when it is not possible to even cool the equipment. APC cooling accessories improve the cooling of the double floor. Rack Air Distribution Unit are dedicated to 3kW power and eliminate the difference between temperature of equipment on the top and bottom of racks. Cooling unit is adapted for mounting in a rack, occupying 2U space. They provide cooling air for better cooling of rack and IT equipment as follows: the ambient air in the server room is drawn into the rack through the raised floor, fans are directed from the bottom to the top of the rack and is sucked into IT equipment. The cooling systems contribute to a better cooling equipment in the rack and reduce the number of failures due to burning which extends the life of equipment.
More information can be found at: http://www.apcc.com/products/resource/include/techspec_index.cfm?base_sku=ACF002
Rack Air Removal Unit Increase in dissipation and dynamic load changes create an environment where traditional air distribution methods are often not effective. Additives to enhance cooling Rack Air Removal Unit Provides efficient cooling of IT equipment and the proper flow of air through the rack, to prevent mixing of hot with room air. Fan is achieved by feeding the free air in the rack, while the exhaust pipe system takes warm air. Automatic fan speed control, automatically adjusts the optimum performance and contribute to a better cooling equipment in the racks. Cooling unit is mounted on the back side of the rack, occupies 0U space and is cost-effective solution from the standpoint of space. Features LCD display and a network card to access over IP, allowing for the management and control of the cooling system.
More information can be found at: http://www.apcc.com/products/resource/include/techspec_index.cfm?base_sku=ACF400
Rack Side Air Distribution Unit
Placement of equipment within the rack has a flow of air from the sides, creating major challenges in terms of cooling. Most racks are designed for the flow of air from the front to the back, so it's very demanding to maintain the optimum temperature of equipment where the flow of air from outside. Rack Side Air Distribution Unit is a unit for cooling which is mounted inside the river, specially configured for equipment where the air circulation from outside. It is recommended that cooled equipment should be placed next to each other (respectively) in the rack, and Distribution Unit Rack Side can be placed above or below equipment. The user configures the direction of air flow by adjusting the fan. Cooling units is adapted for mounting in a rack, occupying 2U space.
More information can be found at: http://www.apcc.com/products/resource/include/techspec_index.cfm?base_sku=ACF202BLK
Roof ventilators are simple and effective solution for cooling equipment, removal of hot air from the rack. The air flow is from bottom to the top of cabinet, the fans are designed to draw warm air. The system is easily installed on the roof of the racks. Models are available that are compatible with the racks 600 and 750mm wide.
More information can be found at: http://www.apcc.com/products/resource/include/techspec_index.cfm?base_sku=ACF502 http://www.apcc.com/products/resource/include/techspec_index.cfm?base_sku=ACF504
|